Zum Hauptinhalt springen

PROFINET Specification

PROFINET , Security

Description:

Overview and guidance for PROFINET specifications
IEC 61158-1

This document provides the overview and guidance how the IEC 61158 series is structured
and how it is related to the profile documents in the IEC 61784 series.
 

Details:
Version: 2.3
Order No.: 2.702
Language: English
______________________________________________________________

Application layer services for decentralized periphery
IEC 61158-5-10

The application service is provided by the application protocol making use of the services available from the data-link or other immediately lower layer. This document defines the application service characteristics that fieldbus applications and/or system management may exploit.

Details:
Version: 2.4MU5
Order No.: 2.712
Language: English

______________________________________________________________

Application layer protocol for decentralized periphery
IEC 61158-6-10

The application protocol provides the application service by making use of the services available from the data-link or other immediately lower layer. The primary aim of this document is to provide a set of rules for communication expressed in terms of the procedures to be carried out by peer application entities (AEs) at the time of communication.

Details:
Version: 2.4MU5
Order No.: 2.722
Language: English

______________________________________________________________

Profiles for decentralized periphery
IEC 61784–2

This part of IEC 61784 provides additional Communication Profiles (CP) to the existing Communication Profile Families (CPF) of IEC 61784–1. These communication profiles are called Real-Time Ethernet communication profiles.
 

Details:
Version: 2.4MU5
Order No.: 2.742
Language: English

 

***************************************************************************************************************************************************************************************

V2.4MU3 mainly focuses on three topics
1. Complete security integration (aligned to IEC/IEEE 60802)
2. IEC/IEEE 60802 conformant end station, bridge, and bridged end station model
3. Enhancements for APL support – avoiding congestion loss

The device model derived from IEEE 802.1Q and a more stringent decoupling of PROFINET
middleware and network interface lead to structural changes in the documents.
➔ This process will be completed in the MU4 with the IEC/IEEE 60802 integration
Complete security integration in Profile, Service and Protocol for all conformance classes.
➔ This process will be completed in the MU4 with the IEC/IEEE 60802 integration
Mixed link speeds are identified as a major threat for creating congestion loss.
➔ Congestion loss prevention completed

 

Main topics for V2.4MU4:

Add application classes Drive and Encoder.

Add Downshift delay and Expected PHY latency variation.

Allow full range for StreamDA destination MAC address.

Adjustment of the DCP filter chaining function.

Adaptation the definition of the required bridge resources to the link-speed and the mandatory buffer time.

Allow the use of link-local IP address according to RFC 3927.

Update the LLDP EXT MIB for MRP interconnection.

Clarification of MRP interconnect encoding.

The IP parameter of the DCP ASE value distinguish between operational and administrative.

Security:

New optional record SNMPReal.

VCI extension for IDevID credentials; used for automated credential commissioning.

Simplify addressing of credential used in record services.

 

 Main topics for V2.4MU5:

Update meaning of the coding of the CycleCounter field for update intervals > 32 ms allowing a more reliable detection of timeliness of data.

Add convention for how to implement adjustable MAUType wit link speed > 100 Mbit/s.

Clarification for PRUNING features according to IO controller, IO devices and bridges.

Security:

Enable RT_CLASS_3 for secure communication.

Introduce new symmetric key update,  adapt AR startup accordingly .

Add security eventing with predefined auditable events for PROFINET and SYSLOG style.

Refinement of related security state machines.

Define ResetToFactory behavior to reset security configuration. 

 

Main topics for Draft 2.4MU6:

  • New optional I&M6 record – OMLOX location
  • New optional I&M7 record – Identification Link
  • Maintenance
  • Security
  • Profile

see attached file "Changes_Draft_24MU6_to_V24MU5.pdg"

________________________________________________________________________________________________________________________________________________________

Drafts for review:

Details:
Version:   d2.4MU6
Order No.:   2.712 / 2.722 / 2.742
Language: English

 

This draft is published for testing and review only. It must not be used for development purposes.

Comments to be submitted to www.profibus-project.com  until February 01, 2025.


***************************************************************************************************************************************************************************************

PROFINET V2.4MU3 is specified in IEC 61158-6-10:2023, IEC 61158-5-10:2023 and IEC 61784-2-3:2023.
These documents can be purchased from the IEC website by using the following link:

http://webstore.iec.ch/
__________________________________________________________________________________________________________________

The vendors who provide products with Media Redundancy functionality are authorized to make electronic copies of the attached (ASCII readable)
LLDP-EXT-IEC61158-TYPE10-MIB file (contained in the 7z file) as well as to publish them on their websites.
__________________________________________________________________________________________________________________
 

Files:
This area is for members only. Please login to access this download.
# Date Filename Type Size
17/11/2010 Overview-for-PI-specs_2702_V23_Oct10.pdf pdf 720 KB
29/04/2020 MIBs.7z 7z 14 KB
21/06/2023 LLDP-EXT-IEC61158-TYPE10-MIB-20230331.mib mib 75 KB
18/04/2024 PN-AL-Services_2712_V24MU5_Mar24.pdf pdf 7 MB
18/04/2024 PN-AL-Protocol_2722_V24MU5_Mar24.pdf pdf 11 MB
18/04/2024 PN-Profiles_2742_V24MU5_Mar24.pdf pdf 2 MB
07/11/2024 PN-AL-services-2712-d24MU6-Oct24.pdf pdf 10 MB
07/11/2024 PN-AL-protocol-2722-d24MU6-Oct24.pdf pdf 11 MB
07/11/2024 PN-Profiles-2742-d24MU6-Oct24.pdf pdf 2 MB
07/11/2024 Changes_Draft_24MU6_to_V24MU5.pdf pdf 119 KB
07/11/2024 Diff_PN_AL_services_2712_d24MU6_to_V24MU5.pdf pdf 11 MB
07/11/2024 Diff_PN_AL_protocol_2722_d24MU6_to_V24MU5.pdf pdf 12 MB
07/11/2024 Diff_PN_Profiles_2742_d24MU6_to_V24MU5.pdf pdf 2 MB

The downloads section on profibus.com offers a wealth of valuable resources that are essential for companies working in industrial automation. These documents, including technical descriptions, installation guides, and white papers, provide detailed insights into the implementation and use of PROFIBUS and PROFINET technologies. By accessing these resources, engineers and technical teams can significantly improve their understanding and efficiency in deploying robust, standardized communication solutions in industrial environments.


For companies looking to gain even more from the PROFIBUS ecosystem, becoming a member of PROFIBUS & PROFINET International (PI) offers additional benefits. Members enjoy exclusive access to advanced technical documentation, expert certification programs, and development tools that can accelerate innovation and ensure compliance with the latest industry standards. Membership also provides networking opportunities with other industry leaders, fostering collaboration and knowledge sharing, which is crucial in staying ahead in the fast-evolving automation landscape.


By joining PI, companies position themselves at the forefront of industrial communication technology, ensuring they remain competitive and well-equipped to tackle future challenges.

PNO PROFIBUS
PI Downloads
PI Downloads
PI Downloads
PI Downloads
PI Downloads
PI Downloads